- Industrial waterproof 5-port M12 Gigabit PoE+ Switch
- 4x10/100/1000M M12 (X-coded) TX 30W PSE + 1x10/100/1000M M12 TX
- Input Voltage: 48-56VDC
- Operating temp.: -40°C to +75°C Wide Range Temperature
- DIN-Rail, Wall Mount
Specifications
|
IEEE Standard |
IEEE802.3 10Base-T Ethernet IEEE802.3u 100Base-TX Fast Ethernet IEEE802.3ab 1000Base-T Gigabit Ethernet IEEE802.3x Flow Control and Back Pressure IEEE802.3af PoE IEEE802.3at PoE+ |
|
|
Switch Architecture |
Back-plane (Switching Fabric): 10Gbps |
|
|
Data Processing |
Store and forward |
|
|
Flow Control |
IEEE 802.3x Flow Control and Back Pressure |
|
|
Jumbo Frame |
9KB |
|
|
MAC Address Table Size |
2K |
|
|
Packet Buffer Size |
1Mbits |
|
|
Network Connector |
5 x M12 X-coded 10/100/1000M auto negotiation, Auto MDI/MDI-X function, Full/Half duplex |
|
|
Network Cable |
UTP/STP Cat.5e or above Cable |
|
|
EIA/TIA-568 (100m) |
||
|
Protocol |
CSMA/CD |
|
|
LED |
Power (Green) ON-Power is detected |
|
|
Port 1 to Port 5: LNK/ACT (Green) ON-M12 port is detected. Flashing-M12 data is transmitting/receiving. PoE (Amber) ON-PSE is activated and PD is detected. |
||
|
Reserve Polarity Protection |
Present |
|
|
Overload Current Protection |
Present |
|
|
Power Supply |
48~56VDC |
|
|
Power Consumption |
5W@48 VDC full load, Without PoE |
|
|
PoE Power |
Input Voltage 48VDC-56VDC PoE power per port 30watts Maximum total power 120Watts at 56VDC input |
|
Operating Temperature |
-40°C to 75°C |
|
Operating Humidity |
5% to 95% (non-condensing) |
|
Storage Temperature |
-40°C to 85°C |
|
MTBF (mean time between failure) |
546613 hours (MIL-HDBK-217F) at 25°C |
|
Housing |
IP67 Protection |
|
Case Dimension (L x W x D) |
220x50x27.7mm |
|
Installation |
Wall Mount included |
|
Certifications |
|
|
Safety |
UL 62368-1 |
|
Safety |
LVD (EN 62368-1) pending |
|
EMC |
CE, FCC |
|
EMI |
CISPR 32, FCC Part 15B Class A |
|
EMS |
IEC 61000-4-2 ESD: Contact: 6KV; Air: 8KV IEC 61000-4-4 EFT: Power: 2KV; Signal: 2KV IEC 61000-4-5 Surge: Power: 2KV; Signal: 2KV |
|
Vibration |
EN 60068-2-6 |
|
Shock |
EN 60068-2-27 |
|
Free Fall |
EN 60068-2-31 |
|
Railroad |
EN 50155 / EN 50121-3-2 |
|
Railroad |
EN 50155 / EN 50121-4 |