H8042ACF AKTIVATECH Unmanaged Industrial Switch 6 port Gigabit PoE+ 4x Gigabit 30W PSE TX + 1x TX/SFP Combo + 1x 100/1000M SFP
- Hardened Industrial 6 port Gigabit PoE+ Switch
- 3 power input 4x Gigabit 30W PSE TX + 1x TX/SFP Combo + 1x 100/1000M SFP
- Support Power 1, Power 2, and Power DIN (for external power adapter)
- Operating temp.: -40°C to +75°C Wide Range Temperature
- DIN-Rail, Wall Mount
Specification
|
IEEE Standard |
IEEE 802.3 10Base-T Ethernet IEEE 802.3af PoE IEEE 802.3at PoE+ |
||
|
Switch Architecture |
Back-plane (Switching Fabric): 12Gbps |
||
|
Data Processing |
Store and Forward |
||
|
Flow Control |
IEEE 802.3x Flow Control and Back Pressure |
||
|
Jumbo Frame |
9KB |
||
|
MAC Address Table Size |
1K |
||
|
Packet Buffer Size |
1M |
||
|
Network Connector |
5 x RJ-45 10/100/1000BaseT(X) auto negotiation, 4 x Gigabit 30W PoE+ 802.3at/af PSE port 2 x SFP 100/1000M BaseX Auto MDI/MDI-X function, Full/Half duplex |
||
|
Network Cable |
UTP/STP Cat.5e or above Cable |
||
|
EIA/TIA-568 (100m) |
|||
|
Protocol |
CSMA/CD |
||
|
LED |
PW1 (Green): ON-Power 1 is detected PW2 (Green): ON-Power 2 is detected PW3 (Amber): ON-Power Din is detected RLY (Amber): ON-Only PW1 or PW2 is connected OFF-Both PW1 and PW2 are connected |
||
|
TX/RJ-45 port (1~4) LNK (Green): ON-TX port is detected Flashing-TX data is transmitting/receiving PoE (Amber): ON-PSE is activated and PD is detected OFF-PSE is detecting PD |
|||
|
SFP port: F5/F6 (Green): ON-SFP port is detected Flashing-SFP data is transmitting/receiving |
|||
|
DIP Switch |
DIP 1: F5: Port F5 SFP on (Default) T5: Port T5 TX on DIP 2: 1000M: SFP 1000M (Default) 100M: SFP 100M |
||
|
Reserve Polarity Protection |
Present |
||
|
Overload Current Protection |
Present |
||
|
Power Supply |
Redundant Dual DC 48V-56V Power Input PoE input 48-56VDC |
||
|
Power Consumption |
5.76W@48 VDC full load, Without PoE |
||
|
Alarm Relay Contact |
Relay outputs with current carrying capacity of 1 A @24VDC, Relay in “open” circuit mode when PW1 and PW2 are connected. In “short” circuit mode when only one power supply is connected. |
|
|
|
PoE power |
PoE power per port 30Watts Maximum total power 120Watts Supports IEEE802.3af/at |
||
|
Removable Terminal Block |
Provide 2 Redundant power, Alarm relay contact, 6 Pin. And circular POWER DIN for power adapter Wire range: 0.34mm^2 to 2.5mm^2 Solid wire (AWG):12-24/14-22 Stranded wire (AWG): 12-24/14-22 Torque:5lb-In/0.5Nm/0.56Nm Wire Strip length: 7-8mm |
||
|
Immunity |
2kV surge protector for DATA port, 2kV surge protector for PoE port |
||
|
Operating Temperature |
-40°C to 75°C |
||
|
Operating Humidity |
5% to 95% (non-condensing) |
||
|
Storage Temperature |
-40°C to 85°C |
||
|
MTBF (mean time between failure) |
525057.45 hrs (Telcordia (Bellcore), GB) at 50°C |
||
|
Housing |
Rugged Metal, IP30 Protection |
||
|
Case Dimension (LxWxD) |
142x36.2x105 mm (LxWxD) |
||
|
Installation |
DIN Rail and Wall Mount options included |
||
Certifications |
|||
|
Safety |
UL 60950-1 |
||
|
Safety |
LVD (EN62368-1) |
||
|
EMC |
CE, FCC, EN 55032/35 |
||
|
EMI |
CISPR 32, FCC Part 15B Class A |
||
|
EMS |
IEC 61000-4-2 ESD: Contact: 6KV; Air: 8KV IEC 61000-4-4 EFT: Power: 2KV; Signal: 2KV IEC 61000-4-5 Surge: Power: 2KV; Signal: 2KV |
||
|
Vibration |
EN 60068-2-6 |
||
|
Shock |
EN 60068-2-27 |
||
|
Free Fall |