H6050 AKTIVATECH Rugged Unmanaged Industrial Switch 5 port 10/100M PoE+ 4x 10/100M TX 30W PSE, 1x 10/100M TX
- Rugged Industrial 5 port 10/100M PoE+ Switch
- 4x 10/100M TX 30W PSE, 1x 10/100M TX, 2KV Surge Immunity
- Supports power 1, power 2, Input Voltage: 48-56VDC
- Operating temp.: -40°C to +75°C Wide Range Temperature
- DIN-Rail, Wall Mount
Specifications:
|
IEEE Standard |
IEEE 802.3 10Base-T Ethernet IEEE 802.3af IEEE 802.3at |
|
|
Switch Architecture |
Back-plane (Switching Fabric): 1Gbps |
|
|
Data Processing |
Store and Forward |
|
|
Flow Control |
IEEE 802.3x Flow Control and Back Pressure |
|
|
MAC Address Table Size |
1K |
|
|
Packet Buffer Size |
448Kbits |
|
|
Network Connector |
5xRJ-45 10/100BaseT(X)
auto negotiation, |
|
|
Network Cable |
UTP/STP Cat.5e or above Cable |
|
|
EIA/TIA-568 (100m) |
||
|
Protocol |
CSMA/CD |
|
|
LED |
PW1 (Green): ON-Power 1 is detected PW2 (Green): ON-Power 2 is detected |
|
|
TX/RJ-45 port: (Port 1~4) LNK (Link/Active) (Green): ON-TX port is detected Flashing-TX data is transmitting/receiving PoE (Amber): ON-PD is detected and PSE is activated OFF-PD is not detected |
||
|
Reserve Polarity Protection |
Present |
|
|
Overload Current Protection |
Present |
|
|
Power Supply |
Redundant Dual DC 48V-56V Power Input |
|
|
Power Consumption |
2.24W@48 VDC full load without PoE |
|
|
PoE power |
PoE power per port 30watts. Maximum total power 90Watts with 56VDC input, Supports IEEE 802.3af/at |
|
|
Removable Terminal Block |
Provide 2 Redundant power, 4 Pin Wire range: 0.34mm^2 to 2.5mm^2 Solid wire (AWG):12-24/14-22 Stranded wire (AWG): 12-24/14-22 Torque:5lb-In/0.5Nm/0.56Nm Wire Strip length: 7-8mm |
|
|
Operating Temperature |
-40°C to 75°C |
|
|
Operating Humidity |
5% to 95% (Non-condensing) |
|
Storage Temperature |
-40°C to 85°C |
|
MTBF (mean time between failure) |
529,755.91 hrs (Telcordia (Bellcore), GB) at 50°C |
|
Housing |
Rugged Metal, IP30 protection |
|
Case Dimension |
103.5 x 32 x 81.5 mm (L x W x D) |
|
Installation |
DIN Rail Mount or Wall Mount |
|
Certifications: |
|
|
Safety |
LVD(EN62368-1) |
|
EMC |
CE, FCC, EN 55032/35 |
|
EMI |
CISPR 32, FCC Part 15B Class A |
|
EMS |
IEC 61000-4-2 ESD: Contact: 6KV; Air: 8KV IEC 61000-4-4 EFT: Power: 2KV; Signal: 2KV IEC 61000-4-5 Surge: Power: 2KV; Signal: 2KV |
|
Vibration |
EN 60068-2-6 |
|
Shock |
EN 60068-2-27 |
|
Free Fall |
EN 60068-2-32 |